955
|
Adjustable Stand
|
Davidson Optronics
|
D-239
|
unkn
|
Very Good |
|
|
Specifications: Designed for Autocollimators or other instruments with barrel diameters of approximately 2.863 inches. Adjustments: 4 degrees elevation, 2 degrees azimuth. Weight 75 lbs.
|
|
861
|
Autocollimator
|
Davidson
|
D-600
|
|
Very Good |
|
|
Specifications: Sensitivity 1/10 second of arc, Accuracy +/- 1/2 second or arc, Aperture dia. 2-3/8 ", Focal length 20 ". Comparison autocollimators meause angular differences between two reflecting surfaces. Needs a transformer and cable to operate. Wooden case is in rough shape but the instrument looks unused.
|
|
1428
|
Automatic Auto Collimator
|
Davidson Optronics
|
D-665-107
|
|
Very Good |
|
|
Specifications: Comes with operation/instruction manual
|
|
1439
|
Comparator
|
Gage Master
|
Series 20
|
1991
|
Very Good |
|
|
Specifications: 14" optical compararator with Autocomp 1 DRO. 48" x 18.5" x 36" LWH apx 145 lbs.
|
|
32
|
Interferometer
|
Davidson
|
D311-L
|
1980
|
Fair |
|
|
Specifications: Working Aperture: 1 1/2", Accuracy: 1/10 Fringe (1/20 Wave), Macroplan Interferometer for measuring flatness of small reflective surfaces. 2X magnification. Needs laser and diffuser, adjustable eyepiece and some springs for bottom of tip/tilt work table, otherwise in good shape
|
|
1354
|
Interferometer
|
Zygo
|
4" PTI with 4 to 6" Beam Expander
|
20
|
Very Good |
|
|
Specifications:
|
|
1353
|
Interferometer
|
Zygo
|
4" PTI
|
20 yrs
|
Fair |
|
|
Specifications: There are no extra features. The Laser is weak.
|
|
70
|
Laser Beam Galilean Collimator
|
Newport Corp
|
T28-100-75
|
1994
|
Excellent |
|
|
Specifications: Input Beam Size (mm) 0.75, Output Beam Size (mm) 100, Range VIS. For bench use.
|
|
1415
|
Optical Profiler
|
Wyko
|
CCT2100
|
|
Excellent |
|
|
Specifications: Has been recently serviced in Jan 2010, computer, CRT, keyboard, base cabinet and operational manual included.
|
|
111
|
OTDR Optical Time Domain Reflectometer
|
Anritsu
|
MW9070A
|
Apx 6 years
|
Excellent |
|
|
Specifications: With 1300 nanometer single mode plug in.
|
|
1134
|
Retinal Camera Polaroid
|
Topcon
|
TRC 50F
|
10 years
|
Excellent |
|
|
Specifications: This camera is a mydriatic camera that is in excellent condition. Manual included. Can be changed to 35 mm camera if desired.
|
|
1132
|
SMI Surface Measurement Instrument
|
Optikos
|
SMI
|
1999
|
Excellent |
|
|
Specifications: The SMI is a high speed surface measurement tool that characterizes spheric, toric and aspheric surfaces of contact lenses, molds and intraocular lenses (IOL). HP Vectra, Running Windows NT 4.0 Version 1.1.7B. Last used on January 31, 2008. Has had very limited usage. Attachments include: Built in 12.7mm contact lens button stage and 12.7mm contact lens blocking arbor stage.
|
|
1156
|
Spectrophotometer
|
Perkin Elmer
|
LAMBDA 25
|
2007
|
Excellent |
|
|
Specifications: UV VIS FIXED RES W/SW V2.8 (Item# L6000BB), Variable angle reflectance accessory (Item# B0137314), Relative specular reflectance accessory -6D (Item# B0086703), Solid Sample holder (Item# B0080822). Used for apx one month.
|
|
1421
|
X-Ray Measurement System
|
Veeco
|
XRF-4200
|
|
Fair |
|
|
Specifications: Needs computer to operate, serial # 4200-0137 Last calibration date 2007. Service manual included.
|
|